01: A-series Flexible Clamp
The design has won the national patent. Patent number: 200,820,118,363.5Technology Highlights:a. C-shaped component has flexibility and can absorb the wires change which caused by thermal expansion and contraction. It can maintain a constan...
02:B-series Equipment Clamp (JM095, JM120, JM150, JM185, JM240)
This is a picture of B-series Equipment Clamp which is connected device (such as mast switch or disconnecting switch) and 95-240 mm2 wire, the junction plate has double holes. Corresponding models are JM095, JM120, JM150, JM185, and JM240. ...
03:B-series Equipment Clamp (JM035, JM050, JM070)
This is a picture of B-series Equipment Clamp which is used to connect device (such as fuse block) and 35-70 mm2 wire Corresponding models are JM035, JM050, and JM070. Technology Highlights:a. It usesoxygen-free copper plate, the surface wa...
04:C-series Connector for Cable and Wire
The design has won the national patent. Patent number: 200820118147.0C-series Connector for Cable and Wire is an innovative product in ShinelandElectric Power Company. The design has won the national patent. Patent number: 200820118147.0.Ap...
05:Conventional type of insulation protective shelter
The role of insulation protective cap is set in the external of C-type cable clamp. Dealing with the place of insulated wire where was peeled to achieve the purpose that is fully insulation. Prevent wire core corrosion caused by water inlet...
06:Thermal type of insulation protective shelter
The role of Thermal type of insulation protective cap is set in the external of C-type cable clamp, Dealing with the place of insulated wire where was peeled to achieve the totally insulated purpose. Prevent corrosion caused by wire core wa...
07:10KV lightening-protection post insulator
This is a multi-function insulator include supporting and fixed wire, lightening-protection, examine electricity, earth connection, suitable for lightening-protection of new Insulation Line.Technology Highlights of this product:a. Giving fu...
08:10KV nonlinearity lightening-protection device (post insulator uses for lightening-protection)
1.applicability:used on line tower which is on 10KV tower distribution insulation line. It is used to support and fix wire. Whenbeing struck by lightning, thelightning current quickly imports earth. It can prevent insulated wire breaking br...
10:10KV Flash Guard Fitting in Insulation Lines(with lightning mark)
It is suited for lightning protection in insulated lines that have been built. It is advised to install on every tower. It has a lightning mark on the top of arcing rod. So we can judge whether here has been suffered by lightning, through o...
11:Rapid Graphite Grounding Device- small-sized GE01
Small-sized GE01applicability:Used for soil whose specific resistance is smaller such as seashore saline soil, paddy soil, fluvo-aquic soils. It is used as electrical equipment grounding such as transformer casing and neutral-point.earth co...
12:Rapid graphite grounding device - common type SM02
Ordinary-sized GE02applicability:It is used in the soil which resistivity is smaller,It is used as electrical equipment grounding such as transformer casing and neutral-point Earth connection of Annular Net Cabinet, Cable Branch Box, Box Tr...
13:Rapid Graphite Grounding Strengthened type GE03
Strengthened type GE03applicability:It is used in the soil which resistivity is bigger,It is used as electrical equipment grounding such as transformer casing and neutral-point earth connection of Annular Net Cabinet, Cable Branch Box, Box ...
14:Intelligent Fault Indicator on overhead line
It is used for indicating the short circuit of aerial line and faulty indication of grounding device. When the line goes wrong, its sign show flip in the day. But in the evening it automatically turns to flash signal.
15:Fault indicator for cable line
It was installed in annular net cabinet,branch Box, box transformer substation on the cable line, used to indicate the cable line short circuit andearth fault.
16:Various kinds of copper-aluminum connecting pipe
Used to the connection of the cable intermediate joint, and it can connect copper-copper,aluminum-aluminum, copper- aluminum. And it can change in diameter to apply to different thickness of cable.
17:Threaded-pipe type transformer clamp
Used to connect transformer bushing and the wire, please specify the type of screw worm on transformer junction pole and conductor type,angle of the clamp.
18:A-series Flexible Clamp(site picture- 10 KV double circuit distribution lines)
This is a picture of Tension Rod on 10KVdouble-circuit distribution lines. The mode of the wire is JKLGYJ-240 insulated conductor. Every primary loop has three lines, total of six joints. The connection of Jumping Line uses A-series of C-ty...
19:A-series Flexible Clamp (enlarged site picture)
This is a picture of Tension Rod Jumping Line on 10KV double-circuit distribution lines whose joint uses C-type cable clamp. Each connector only needs to install one C-type cable clamp (A-series). The outside of the clamp was covered with e...
20:A-series Flexible Clamp (site picture- T-junction cable line of 10 KV double circuit distribution lines)
This is a picture of T-junction cable line of 10 KV double circuit distribution lines. The top is JKLGYJ-240 double circuit insulated conductor, and the bottom connects cable. It uses C-type cable clamp (A-series) JM331 at the T-junction of...
21:A-series Flexible Clamp(site picture-10KV service entrance branch)
This is a picture of mainline on 10 KV distribution lines branching to the user. The top of the main line is insulated conductor which model is JKLGYJ-240. The service entrance is JKLGYJ-50 insulated conductor. The T-junction between servic...
22:06: A-series Flexible Clamp(site picture-0.4KV service entrance branch)
This is a picture of T-junction between 0.4KV mainline and service entrance. The mainline uses JKLYJ-95 insulated conductor, the service entrance is YJLV-50 electric cable. The joint uses A-series Flexible Clamp and the model is JM21. The o...
23:B-series Equipment Clamp (site picture- horizontal terminal board on mast switch)
This is a picture of mast switch on 10KV distribution line. The joint between the junction plate of mast switch and the wire uses B-series Equipment Clamp. The model of the wire is JKLGY-240 insulated conductor and the B-series Equipment Cl...
24:B-series Equipment Clamp (site picture- 60 degrees terminal board on mast switch)
This is a picture of mast switch on 10KV distribution line. The junction plate on mast switch show 60-degree angle. The connection with the wire uses B-series Equipment Clamp. The type of the wire is JKLGYJ-240 insulated conductor. The mode...
25:B-series Equipment Clamp (site picture-knife switch)
This is a picture of B-series Equipment Clamp which connects disconnector and insulated conductor. The right-hand side of clamp connects insulated conductor, and the left connects the terminal of disconnector by a diplopore junction plate. ...
26:B-series Equipment Clamp (site picture-10KV service entrance drop-fuse)
This is a picture of Drop-fuse which top uses B-series Equipment Clamp, and the bottom of terminal clamp is connected to the junction plate of Drop-fuse by a junction plate, the top connects with conducting wire which model is JKLGYJ-50 ins...
27:C-series Connector for Cable and Wire (site picture-six-time dead-end steel tower)
This is a picture of terminal tower on 10KV distribution line which uses C-series Connector for Cable and Wire. On the right of the tower is JKLGYJ-240 aerial insulated cable, and the left is YJV-300 copper core cable. Implementation proced...
28:C-series Connector for Cable and Wire (site picture)
This is a site picture of C-series Connector for Cable and Wire. The top is JKLGYJ-50Overhead Insulated Wire and the below is YJLV-70aluminum cable. The mode of clamp is JM050-L070 (the front is the type of the wire, and the back is the typ...
29:Type-selection Table for Rapid Graphite Grounding Device
This is a type-selection table for Rapid Graphite Grounding Device.
30:Installation Steps Chart of Rapid Graphite Grounding Device.
This is an Installation Steps Chart of Rapid Graphite Grounding Device.